An integrated Taguchi and response surface methodological approach for the optimization of an HPLC method to determine glimepiride in a supersaturatable self-nanoemulsifying formulation

We studied the application of Taguchi orthogonal array (TOA) design during the development of an isocratic stability indicating HPLC method for glimepiride as per TOA design; twenty-seven experiments were conducted by varying six chromatographic factors. Percentage of organic phase was the most sign...

ver descrição completa

Na minha lista:
Detalhes bibliográficos
Publicado no:Saudi Pharm J
Main Authors: Dash, Rajendra Narayan, Mohammed, Habibuddin, Humaira, Touseef
Formato: Artigo
Idioma:Inglês
Publicado em: Elsevier 2016
Assuntos:
Acesso em linha:https://ncbi.nlm.nih.gov/pmc/articles/PMC4720010/
https://ncbi.nlm.nih.gov/pubmed/26903773
https://ncbi.nlm.nih.govhttp://dx.doi.org/10.1016/j.jsps.2015.03.004
Tags: Adicionar Tag
Sem tags, seja o primeiro a adicionar uma tag!