Sensitive and Rapid HPLC Method for Determination of Memantine in Human Plasma Using OPA Derivatization and Fluorescence Detection: Application to Pharmacokinetic Studies

A rapid, sensitive and reproducible HPLC method was developed and validated for the analysis of memantine in human plasma after derivatization with o-phthaldialdehyde (OPA) and fluorescence detection. Amantadine was used as internal standard. The derivatized memantine and amantadine were eluted in l...

ver descrição completa

Na minha lista:
Detalhes bibliográficos
Main Authors: Zarghi, Afshin, Shafaati, Alireza, Foroutan, Seyed Mohsen, Khoddam, Arash, Madadian, Babak
Formato: Artigo
Idioma:Inglês
Publicado em: Österreichische Apotheker-Verlagsgesellschaft 2010
Assuntos:
Acesso em linha:https://ncbi.nlm.nih.gov/pmc/articles/PMC3007610/
https://ncbi.nlm.nih.gov/pubmed/21179320
https://ncbi.nlm.nih.govhttp://dx.doi.org/10.3797/scipharm.1008-17