The Effects of Cyclic Loading and Motion on the Implant–Cement Interface and Cement Mantle of PEEK and Cobalt–Chromium Femoral Total Knee Arthroplasty Implants: A Preliminary Study

This study investigated the fixation of a cemented PEEK femoral TKA component. PEEK and CoCr implants were subjected to a walking gait cycle for 10 million cycles (MC), 100,000 cycles or 0 cycles (unloaded control). A method was developed to assess the fixation at the cement–implant interface, which...

Descripció completa

Guardat en:
Dades bibliogràfiques
Publicat a:Materials (Basel)
Autors principals: de Ruiter, Lennert, Cowie, Raelene M., Jennings, Louise M., Briscoe, Adam, Janssen, Dennis, Verdonschot, Nico
Format: Artigo
Idioma:Inglês
Publicat: MDPI 2020
Matèries:
Accés en línia:https://ncbi.nlm.nih.gov/pmc/articles/PMC7435552/
https://ncbi.nlm.nih.gov/pubmed/32722599
https://ncbi.nlm.nih.govhttp://dx.doi.org/10.3390/ma13153323