The end-expiratory occlusion test for detecting preload responsiveness: a systematic review and meta-analysis

BACKGROUND: We performed a systematic review and meta-analysis of studies assessing the end-expiratory occlusion test (EEXPO test)-induced changes in cardiac output (CO) measured by any haemodynamic monitoring device, as indicators of preload responsiveness. METHODS: MEDLINE, EMBASE and Cochrane Dat...