Načítá se...
The end-expiratory occlusion test for detecting preload responsiveness: a systematic review and meta-analysis
BACKGROUND: We performed a systematic review and meta-analysis of studies assessing the end-expiratory occlusion test (EEXPO test)-induced changes in cardiac output (CO) measured by any haemodynamic monitoring device, as indicators of preload responsiveness. METHODS: MEDLINE, EMBASE and Cochrane Dat...
Uloženo v:
| Vydáno v: | Ann Intensive Care |
|---|---|
| Hlavní autoři: | , , , , |
| Médium: | Artigo |
| Jazyk: | Inglês |
| Vydáno: |
Springer International Publishing
2020
|
| Témata: | |
| On-line přístup: | https://ncbi.nlm.nih.gov/pmc/articles/PMC7246264/ https://ncbi.nlm.nih.gov/pubmed/32449104 https://ncbi.nlm.nih.govhttp://dx.doi.org/10.1186/s13613-020-00682-8 |