BACKGROUND: To improve urinary tract infection detection, we evaluated the specificity and sensitivity of Loop-mediated isothermal Amplification Method (LAMP) for detection of the Eschericia coli (E. coli) in urine samples, for the first time. METHODS: Primers were designed to target the malB gene o...