Neochord Placement vs Triangular Resection in Mitral Valve Repair: A Finite Element Model

BACKGROUND: Recurrent mitral regurgitation after mitral valve repair is common, occurring in nearly 50% of patients within 10 years of surgery. Durability of repair is partly related to stress distribution over the mitral leaflets. We hypothesized that repair with neochords (NC) results in lower str...