Neochord Placement vs Triangular Resection in Mitral Valve Repair: A Finite Element Model

BACKGROUND: Recurrent mitral regurgitation after mitral valve repair is common, occurring in nearly 50% of patients within 10 years of surgery. Durability of repair is partly related to stress distribution over the mitral leaflets. We hypothesized that repair with neochords (NC) results in lower str...

Descrición completa

Gardado en:
Detalles Bibliográficos
Publicado en:J Surg Res
Main Authors: Morgan, Ashley E, Pantoja, Joe L, Grossi, Eugene A, Ge, Liang, Weinsaft, Jonathan W, Ratcliffe, Mark B.
Formato: Artigo
Idioma:Inglês
Publicado: 2016
Assuntos:
Acceso en liña:https://ncbi.nlm.nih.gov/pmc/articles/PMC5142216/
https://ncbi.nlm.nih.gov/pubmed/27916382
https://ncbi.nlm.nih.govhttp://dx.doi.org/10.1016/j.jss.2016.07.011