Development of a Hydrogen Sulfide End-of-Service-Life Indicator for Respirator Cartridges Using Cobinamide

An inexpensive paper-based sensor was developed for detecting low ppm concentrations of hydrogen sulfide gas. A piece of filter paper containing aquohydroxocobinamide [OH(H2O)Cbi] was placed on the end of a bifurcated optical fiber, and the reflectance spectrum of the OH(H2O)Cbi was monitored during...