Kinematic Robot-Based Evaluation Scales and Clinical Counterparts to Measure Upper Limb Motor Performance in Patients With Chronic Stroke
BACKGROUND: Human-administered clinical scales are the accepted standard for quantifying motor performance of stroke subjects. Though widely accepted, these measurement tools are limited by interrater and intrarater reliability and are time consuming to apply. In contrast, robot-based measures are h...