Development and validation of a high-performance liquid chromatography-mass spectrometric assay for the determination of 17-alpha Hydroxyprogesterone Caproate (17-OHPC) in human plasma
A sensitive and specific method for the determination of 17α-hydroxyprogesterone caproate (17-OHPC) in human plasma using high performance liquid chromatography and mass spectrometry has been developed and validated. Plasma samples were processed by a solid phase extraction (SPE) procedure using Oas...