Experience with Electron Microscopy in the Differential Diagnosis of Smallpox

The usefulness of negative-contrast electron microscopy in the rapid differential diagnosis of poxvirus and herpesvirus exanthems is described in this study of 301 specimens from patients with vesicular exanthematous diseases. Specimens from patients with smallpox, various forms of vaccination compl...