Imaging of Endogenous Exchangeable Proton Signals in the Human Brain Using Frequency Labeled Exchange (FLEX) Transfer Imaging
PURPOSE: To image endogenous exchangeable proton signals in the human brain using a recently reported method called frequency labeled exchange transfer (FLEX) MRI. METHODS: As opposed to labeling exchangeable protons using saturation (i.e., chemical exchange saturation transfer, or CEST), FLEX label...