A carregar...
Imaging of Endogenous Exchangeable Proton Signals in the Human Brain Using Frequency Labeled Exchange (FLEX) Transfer Imaging
PURPOSE: To image endogenous exchangeable proton signals in the human brain using a recently reported method called frequency labeled exchange transfer (FLEX) MRI. METHODS: As opposed to labeling exchangeable protons using saturation (i.e., chemical exchange saturation transfer, or CEST), FLEX label...
Na minha lista:
| Main Authors: | , , , , |
|---|---|
| Formato: | Artigo |
| Idioma: | Inglês |
| Publicado em: |
2013
|
| Assuntos: | |
| Acesso em linha: | https://ncbi.nlm.nih.gov/pmc/articles/PMC3606647/ https://ncbi.nlm.nih.gov/pubmed/23400954 https://ncbi.nlm.nih.govhttp://dx.doi.org/10.1002/mrm.24655 |
| Tags: |
Adicionar Tag
Sem tags, seja o primeiro a adicionar uma tag!
|