Graphite/InP and graphite/GaN Schottky barriers with electrophoretically deposited Pd or Pt nanoparticles for hydrogen detection
Large attention has been devoted worldwide to the investigation of hydrogen sensors based on various Schottky diodes. We prepared graphite semimetal Schottky contacts on polished n-InP and n-GaN wafers partly covered with nanoparticles of catalytic metals Pd or Pt by applying colloidal graphite. Met...