24-hour glucose profiles during continuous or oscillatory insulin infusion. Demonstration of the functional significance of ultradian insulin oscillations.

Under basal and stimulated conditions, normal insulin secretion oscillates with periods in the ultradian 100-150-min range. To test the hypothesis that oscillatory insulin delivery is more efficient in reducing blood glucose levels than continuous administration, nine normal young men were each stud...

Fuld beskrivelse

Na minha lista:
Bibliografiske detaljer
Udgivet i:J Clin Invest
Principais autores: Sturis, J, Scheen, A J, Leproult, R, Polonsky, K S, van Cauter, E
Format: Artigo
Sprog:Inglês
Udgivet: American Society for Clinical Investigation 1995