The electrophysiologic effects of low and high digoxin concentrations on isolated mammalian cardiac tissue: reversal by digoxin-specific antibody

The effects of digoxin on electrophysiologic properties were evaluated in isolated perfused cardiac tissue. In canine Purkinje fiber (PF)-ventricular muscle (VM) preparations, control measurements, using microelectrode technique, were made of: resting potential (RP), action potential (AP) amplitude,...