Optical coherence tomography evaluation of zotarolimus-eluting stents at 9-month follow-up: comparison with sirolimus-eluting stents
OBJECTIVE: To evaluate the vascular response at 9 months after zotarolimus-eluting stent (ZES; Endeavor) implantation using optical coherence tomography (OCT). These findings were compared with those after implantation of a sirolimus-eluting stent (SES; Cypher Select). DESIGN: Cross-sectional observ...
שמור ב:
| Main Authors: | , , , , , , , , , |
|---|---|
| פורמט: | Artigo |
| שפה: | Inglês |
| יצא לאור: |
BMJ Group
2009
|
| נושאים: | |
| גישה מקוונת: | https://ncbi.nlm.nih.gov/pmc/articles/PMC2775122/ https://ncbi.nlm.nih.gov/pubmed/19535352 https://ncbi.nlm.nih.govhttp://dx.doi.org/10.1136/hrt.2009.167759 |