Multiple Sequential Complications After Sirolimus-Eluting Stent Implantation: Very Late Stent Thrombosis, Stent Fracture, In-Stent Restenosis, and Peri-Stent Aneurysm
A 55-year-old male patient presented with an acute myocardial infarction. A sirolimus-eluting stent (SES) was implanted in the proximal left anterior descending artery (LAD). Eight months later, there was a newly developed distal LAD lesion. An additional SES was implanted. Twenty-eight months after...