Caricamento...
Very late thrombosis after implantation of sirolimus eluting stent
Stent thrombosis after sirolimus eluting stent implantation has been reported to occur at six hours to 375 days after the procedure and usually within the two weeks after discontinuation of antiplatelet medication. A case is reported of very late stent thrombosis after 17 months of sirolimus eluting...