Statistical determination of endotoxin content in influenza virus vaccine by the limulus amoebocyte lysate test.

To determine laboratory-to-laboratory variability of the limulus amoebocyte lysate (LAL) test for evaluating endotoxin content in influenza virus vaccine, a collaborative study was designed. Participants were six influenza virus vaccine manufacturers and the Bureau of Biologics (BoB). Lysate lot 116...