New cause for false-positive results with the Pastorex Aspergillus antigen latex agglutination test.

The Pastorex Aspergillus antigen test for detection of Aspergillus galactomannan antigen in the sera of patients with invasive aspergillosis is used in many clinical laboratories. A serum sample contaminated with Penicillium chrysogenum gave a strongly positive reaction (1:128) which was heat stable...