False-negative cerebrospinal fluid cryptococcal latex agglutination tests for patients with culture-positive cryptococcal meningitis.

Three cases of false-negative cerebrospinal fluid latex agglutination test results for patients with culture-positive cryptococcal meningitis are reported. False-negative results occurred in settings of low cryptococcal antigen concentrations in cerebrospinal fluid and were dependent on the latex ag...