Chargement en cours...
Finger-prick blood samples can be used interchangeably with venous samples for CD4 cell counting indicating their potential for use in CD4 rapid tests
The objective of this study was to investigate the utility of finger-prick blood samples for CD4 counting. We estimated agreement between CD4 counts in paired finger-prick and venous samples from 110 HIV-infected Malawian adults. Bias was 6.6 cells/ul (limits of agreement −50.7 and 63.7 cells/ul) fo...
Enregistré dans:
| Auteurs principaux: | , , , , , |
|---|---|
| Format: | Artigo |
| Langue: | Inglês |
| Publié: |
2007
|
| Sujets: | |
| Accès en ligne: | https://ncbi.nlm.nih.gov/pmc/articles/PMC2408852/ https://ncbi.nlm.nih.gov/pubmed/17630562 https://ncbi.nlm.nih.govhttp://dx.doi.org/10.1097/QAD.0b013e32823bcb03 |
| Tags: |
Ajouter un tag
Pas de tags, Soyez le premier à ajouter un tag!
|