Wordt geladen...

Finger-prick blood samples can be used interchangeably with venous samples for CD4 cell counting indicating their potential for use in CD4 rapid tests

The objective of this study was to investigate the utility of finger-prick blood samples for CD4 counting. We estimated agreement between CD4 counts in paired finger-prick and venous samples from 110 HIV-infected Malawian adults. Bias was 6.6 cells/ul (limits of agreement −50.7 and 63.7 cells/ul) fo...

Volledige beschrijving

Bewaard in:
Bibliografische gegevens
Hoofdauteurs: MacLennan, Calman A., van Oosterhout, Joep J. G., White, Sarah A., Drayson, Mark T., Zijlstra, Eduard E, Molyneux, Malcolm E.
Formaat: Artigo
Taal:Inglês
Gepubliceerd in: 2007
Onderwerpen:
Online toegang:https://ncbi.nlm.nih.gov/pmc/articles/PMC2408852/
https://ncbi.nlm.nih.gov/pubmed/17630562
https://ncbi.nlm.nih.govhttp://dx.doi.org/10.1097/QAD.0b013e32823bcb03
Tags: Voeg label toe
Geen labels, Wees de eerste die dit record labelt!