Comparison of direct machine parameter optimization versus fluence optimization with sequential sequencing in IMRT of hypopharyngeal carcinoma

BACKGROUND: To evaluate the effects of direct machine parameter optimization in the treatment planning of intensity-modulated radiation therapy (IMRT) for hypopharyngeal cancer as compared to subsequent leaf sequencing in Oncentra Masterplan v1.5. METHODS: For 10 hypopharyngeal cancer patients IMRT...

Täydet tiedot

Tallennettuna:
Bibliografiset tiedot
Päätekijät: Dobler, Barbara, Pohl, Fabian, Bogner, Ludwig, Koelbl, Oliver
Aineistotyyppi: Artigo
Kieli:Inglês
Julkaistu: BioMed Central 2007
Aiheet:
Linkit:https://ncbi.nlm.nih.gov/pmc/articles/PMC2075520/
https://ncbi.nlm.nih.gov/pubmed/17822529
https://ncbi.nlm.nih.govhttp://dx.doi.org/10.1186/1748-717X-2-33