Yüklüyor......
Comparison of direct machine parameter optimization versus fluence optimization with sequential sequencing in IMRT of hypopharyngeal carcinoma
BACKGROUND: To evaluate the effects of direct machine parameter optimization in the treatment planning of intensity-modulated radiation therapy (IMRT) for hypopharyngeal cancer as compared to subsequent leaf sequencing in Oncentra Masterplan v1.5. METHODS: For 10 hypopharyngeal cancer patients IMRT...
Kaydedildi:
| Asıl Yazarlar: | , , , |
|---|---|
| Materyal Türü: | Artigo |
| Dil: | Inglês |
| Baskı/Yayın Bilgisi: |
BioMed Central
2007
|
| Konular: | |
| Online Erişim: | https://ncbi.nlm.nih.gov/pmc/articles/PMC2075520/ https://ncbi.nlm.nih.gov/pubmed/17822529 https://ncbi.nlm.nih.govhttp://dx.doi.org/10.1186/1748-717X-2-33 |
| Etiketler: |
Etiketle
Etiket eklenmemiş, İlk siz ekleyin!
|