An alkaline approach to treating cooling towers for control of Legionella pneumophila.

Earlier field and laboratory studies have shown that Legionella species survive and multiply in the pH range 5.5 to 9.2. Additionally, the technical feasibility of operating cooling towers at elevated alkalinities and pH has previously been documented by published guidelines. The guidelines indicate...

Descripció completa

Guardat en:
Dades bibliogràfiques
Publicat a:Appl Environ Microbiol
Autors principals: States, S J, Conley, L F, Towner, S G, Wolford, R S, Stephenson, T E, McNamara, A M, Wadowsky, R M, Yee, R B
Format: Artigo
Idioma:Inglês
Publicat: American Society for Microbiology (ASM) 1987
Matèries:
Accés en línia:https://ncbi.nlm.nih.govhttps://pmc.ncbi.nlm.nih.gov/articles/PMC203997/
https://ncbi.nlm.nih.govhttps://pubmed.ncbi.nlm.nih.gov/3662515/
https://ncbi.nlm.nih.govhttps://doi.org/10.1128/aem.53.8.1775-1779.1987
Etiquetes: Afegir etiqueta