Influence of Assay Methodology on the Measurement of Free Serum Ceftriaxone Concentrations

The influence of assay methodology on the measurement of the active free fraction of ceftriaxone in plasma was determined. The free fraction was measured by three methods: agar diffusion bioassay, precipitation of plasma protein with methanol followed by high-performance liquid chromatography (HPLC)...