Responsitivity Measurement of a Lorentz Force Transducer for Homogeneous and Inhomogeneous Magnetic Fields

This paper reports a MEMS gradiometer consisting of two independent, laterally oscillating masses on a single chip with integrated optical readout featuring a responsitivity of 35V/T at resonant operation. The symmetrical design of the two masses offers high accuracy and low cost by using convention...

Volledige beschrijving

Bewaard in:
Bibliografische gegevens
Hoofdauteurs: Matthias Kahr, Michael Stifter, Harald Steiner, Wilfried Hortschitz, Gabor Kovacs, Andreas Kainz, Johannes Schalko, Franz Keplinger
Formaat: Artigo
Taal:Inglês
Gepubliceerd in: MDPI AG 2018-12-01
Reeks:Proceedings
Onderwerpen:
Online toegang:https://www.mdpi.com/2504-3900/2/13/843