Neutron room return effect
The coefficient that relates the neutron source strength and room surface area with the thermal neutron fluence rates has been calculated for neutrons whose energy goes from 1 eV to 20 MeV. This coefficient was calculated using Monte Carlo methods for several room's radii where a point-like source w...