Neutron room return effect

The coefficient that relates the neutron source strength and room surface area with the thermal neutron fluence rates has been calculated for neutrons whose energy goes from 1 eV to 20 MeV. This coefficient was calculated using Monte Carlo methods for several room's radii where a point-like source w...

Ful tanımlama

Kaydedildi:
Detaylı Bibliyografya
Yayımlandı:Revista Mexicana de Física
Asıl Yazarlar: H.R. Vega-Carrillo, E. Gallego, E. Manzanares-Acuña, A. Lorente, R. Barquero, A. Martin-Martin, J.L. Gutierrez-Villanueva
Materyal Türü: Artigo
Dil:Inglês
Baskı/Yayın Bilgisi: Sociedad Mexicana de Física A.C. 2008
Konular:
Online Erişim:https://www.redalyc.org/articulo.oa?id=57019064015