RESIDENSE TIME EFFECTS ON THE NOX REMOVAL EFFICIENCY IN TWO DIFFERENT DIELECTRIC BARRIER DISCHARGE CELL

Experimental tests of the removal of NOx compounds were carried out in two dielectric barrierdischarge cells (DBD) reactors at Physics plasma laboratory of Mexico Nuclear center Twodifferent geometries of these reactor were studied, one circular 11.94 cm diameter, and anotherrectangular,16x7 cm, bot...