CENTRIFUGAL FAN IMPELLER FAILURE ANALYSIS USING FINITE ELEMENTS
This article shows the failure analysis assisted with finite element modeling of a centrifugal fan impeller that was originally part of the burner of a 1175 kW [120 bhp] saturated steam boiler. The linear stress and vibration modes model pointed to the origin of the apparently sudden failure.