Stability of Plasma Human Immunodeficiency Virus Load in VACUTAINER PPT Plasma Preparation Tubes during Overnight Shipment

VACUTAINER PPT plasma preparation tubes were evaluated to determine the effects of various handling and shipping conditions on plasma human immunodeficiency virus (HIV) load determinations. Plasmas obtained from PPT tubes stored and shipped under nine different conditions were compared to convention...

Szczegółowa specyfikacja

Zapisane w:
Opis bibliograficzny
Wydane w:J Clin Microbiol
Główni autorzy: Holodniy, Mark, Rainen, Lynne, Herman, Steve, Yen-Lieberman, Belinda
Format: Artigo
Język:Inglês
Wydane: American Society for Microbiology (ASM) 2000
Hasła przedmiotowe:
Dostęp online:https://ncbi.nlm.nih.govhttps://pmc.ncbi.nlm.nih.gov/articles/PMC88717/
https://ncbi.nlm.nih.govhttps://pubmed.ncbi.nlm.nih.gov/10618109/
https://ncbi.nlm.nih.govhttps://doi.org/10.1128/jcm.38.1.323-326.2000