Brucella abortus Infection Acquired in Microbiology Laboratories

We report an outbreak of laboratory-acquired Brucella abortus infection originating in the accidental breakage of a centrifuge tube. A total of 12 laboratory workers were infected (attack rate of 31%), with an incubation time ranging from 6 weeks to 5 months. Antibody titers were evaluated weekly in...