Breakage of sliding hip screw after fixation of pertrochanteric hip fracture: A rare complication
INTRODUCTION: The authors report a rare case of lag screw breakage in a patient treated using locking DHS with home-made trochanteric stabilizing plate (TSP) for pertrochanteric hip fracture. CASE PRESENTATION: A 67 year-old female was operated for pertrochanteric hip fracture with incompetent later...