Single-loop bi-atrial tachycardia with presumed conduction block across an anteroseptal mitral ablation line: A case report: Bi-AT after septal mitral isthmus ablation

A 64-year-old man with no previous medical history underwent catheter ablation (CA) by right pulmonary vein isolation and creation of an anteroseptal mitral isthmus (MI) line for peri-mitral atrial flutter. Since atrial tachycardia (AT) recurred with palpitation 4 months later, a second CA session w...