Mechanical Anastomotic Coupling Device versus Hand-sewn Venous Anastomosis in Head and Neck Reconstruction—An Analysis of 1694 Venous Anastomoses
Background There is a steep learning curve to attain a consistently good result in microvascular surgery. The venous anastomosis is a critical step in free-tissue transfer. The margin of error is less and the outcome depends on the surgeon’s skill and technique. Mechanical anastomotic coupling devi...