The dependences of phase velocity and dispersion on trabecular thickness and spacing in trabecular bone-mimicking phantoms

Frequency-dependent phase velocity was measured in trabecular-bone-mimicking phantoms consisting of two-dimensional arrays of parallel nylon wires (simulating trabeculae) with thicknesses ranging from 152 – 305 microns and spacings ranging from 700 – 1000 microns. Phase velocity varied approximately...

Volledige beschrijving

Bewaard in:
Bibliografische gegevens
Gepubliceerd in:J Acoust Soc Am
Hoofdauteur: Wear, Keith A.
Formaat: Artigo
Taal:Inglês
Gepubliceerd in: 2005
Onderwerpen:
Online toegang:https://ncbi.nlm.nih.gov/pmc/articles/PMC8215567/
https://ncbi.nlm.nih.gov/pubmed/16158673
https://ncbi.nlm.nih.govhttp://dx.doi.org/10.1121/1.1940448