Caricamento...
Ammonia Gas Sensor Based on Graphene Oxide-Coated Mach-Zehnder Interferometer with Hybrid Fiber Structure
A graphene oxide-coated in-fiber Mach-Zehnder interferometer (MZI) formed with a multimode fiber-thin core fiber-multimode fiber (MMF-TCF-MMF) is proposed and experimentally demonstrated for ammonia gas (NH(3)) sensing. The MZI structure is composed of two segments of MMF of length 2 mm, with a flam...
Salvato in:
| Pubblicato in: | Sensors (Basel) |
|---|---|
| Autori principali: | , , , , , |
| Natura: | Artigo |
| Lingua: | Inglês |
| Pubblicazione: |
MDPI
2021
|
| Soggetti: | |
| Accesso online: | https://ncbi.nlm.nih.gov/pmc/articles/PMC8200086/ https://ncbi.nlm.nih.gov/pubmed/34199927 https://ncbi.nlm.nih.govhttp://dx.doi.org/10.3390/s21113886 |