Virtual Monochromatic Image Quality from Dual-Layer Dual-Energy Computed Tomography for Detecting Brain Tumors
OBJECTIVE: To evaluate the usefulness of virtual monochromatic images (VMIs) obtained using dual-layer dual-energy CT (DL-DECT) for evaluating brain tumors. MATERIALS AND METHODS: This retrospective study included 32 patients with brain tumors who had undergone non-contrast head CT using DL-DECT. Am...