Yüklüyor......

The SMART Registry: Long-Term Results on the Utility of the Penumbra SMART COIL System for Treatment of Intracranial Aneurysms and Other Malformations

Introduction: Penumbra SMART COIL® (SMART) System is a novel generation embolic coil with varying stiffness. The study purpose was to report real-world usage of the SMART System in patients with intracranial aneurysms (ICA) and non-aneurysm vascular lesions. Materials and Methods: The SMART Registry...

Ful tanımlama

Kaydedildi:
Detaylı Bibliyografya
Yayımlandı:Front Neurol
Asıl Yazarlar: Spiotta, Alejandro M., Park, Min S., Bellon, Richard J., Bohnstedt, Bradley N., Yoo, Albert J., Schirmer, Clemens M., DeLeacy, Reade A., Fiorella, David J., Woodward, B. Keith, Hawk, Harris E., Nanda, Ashish, Zaidat, Osama O., Sunenshine, Peter J., Liu, Kenneth C., Kabbani, Mouhammed R., Snyder, Kenneth V., Sivapatham, Thinesh, Dumont, Travis M., Reeves, Alan R., Starke, Robert M.
Materyal Türü: Artigo
Dil:Inglês
Baskı/Yayın Bilgisi: Frontiers Media S.A. 2021
Konular:
Online Erişim:https://ncbi.nlm.nih.gov/pmc/articles/PMC8076606/
https://ncbi.nlm.nih.gov/pubmed/33927680
https://ncbi.nlm.nih.govhttp://dx.doi.org/10.3389/fneur.2021.637551
Etiketler: Etiketle
Etiket eklenmemiş, İlk siz ekleyin!