Selective Lumbar Nerve Root Blocks with CT Fluoroscopic Guidance: Technique, Results, Procedure Time, and Radiation Dose
Summary: CT fluoroscopy may be used as a rapid and effective means of guiding needle placement when performing selective lumbar nerve root blocks. In this set of patients, the average external radiation dose was 0.73 mrem per procedure, with an average of 2 seconds of CT-fluoroscopy time and four im...
Na minha lista:
| Udgivet i: | AJNR Am J Neuroradiol |
|---|---|
| Hovedforfatter: | |
| Format: | Artigo |
| Sprog: | Inglês |
| Udgivet: |
American Society of Neuroradiology
2004
|
| Fag: | |
| Online adgang: | https://ncbi.nlm.nih.gov/pmc/articles/PMC7976407/ https://ncbi.nlm.nih.gov/pubmed/15502144 |