Recanalization by Mechanical Embolus Disruption during Intra-Arterial Thrombolysis in the Carotid Territory

BACKGROUND AND PURPOSE: Mechanical disruption of a clot with a microcatheter and a guidewire has not been detailed in conjunction with intra-arterial thrombolysis in patients with acute ischemic stroke. The purpose of this study was to evaluate the efficacy of mechanical disruption of an embolus in...