Predictors of Incomplete Occlusion following Pipeline Embolization of Intracranial Aneurysms: Is It Less Effective in Older Patients?

BACKGROUND AND PURPOSE: Flow diversion with the Pipeline Embolization Device (PED) for the treatment of intracranial aneurysms is associated with a high rate of aneurysm occlusion. However, clinical and radiographic predictors of incomplete aneurysm occlusion are poorly defined. In this study, predi...

Descripció completa

Guardat en:
Dades bibliogràfiques
Publicat a:AJNR Am J Neuroradiol
Autors principals: Adeeb, N., Moore, J.M., Wirtz, M., Griessenauer, C.J., Foreman, P.M., Shallwani, H., Gupta, R., Dmytriw, A.A., Motiei-Langroudi, R., Alturki, A., Harrigan, M.R., Siddiqui, A.H., Levy, E.I., Thomas, A.J., Ogilvy, C.S.