Correlation between activated clotting time monitoring and heparin concentration measurement in a patient with antiphospholipid syndrome during cardiac valve surgery: a case report
BACKGROUND: Anticoagulation management of patients with antiphospholipid syndrome (APS) undergoing cardiac surgery is challenging due to the prolongation of activated clotting time (ACT). Currently, no study has compared the utility of ACT monitoring using the Hemochron Jr. Signature+ and that of he...