Manipulation of Tibial Component to Ensure Avoidance of Bearing Separation from the Vertical Wall of Tibial Component in Oxford Unicompartmental Arthroplasty
In Oxford unicompartmental knee arthroplasty, the relationship between the mobile bearing and the vertical wall of the tibial tray is important in preventing bearing dislocation. Separation of the bearing from the vertical wall can cause spinning of the bearing with an increased risk of subsequent d...