Evaluation of the Effectiveness of Two Automated Room Decontamination Devices Under Real-Life Conditions

To evaluate the effectiveness of automated room decontamination devices, a common aerosolized hydrogen peroxide (aHP) as well as a recent gaseous ozone-based device, which produces the disinfectant reagent without the need of consumables, were tested under real-life conditions. Twenty-two contaminat...