Simulated auditory fiber myelination heterogeneity desynchronizes population responses to electrical stimulation limiting inter-aural timing difference representation

Auditory nerve responses to electrical stimulation exhibit aberrantly synchronous response latencies to low-rate pulse trains, nevertheless, cochlear implant users generally have elevated inter-aural timing difference detection thresholds. These findings present an apparent paradox in which single u...