Preoperative Localization of Breast MRI Lesions: MRI-guided Marker Placement With Radioactive Seed Localization as an Alternative to MRI-guided Wire Localization
OBJECTIVE: Preoperative MRI-guided wire localization (MWL) presents challenges to both the physician and patient. In this study, we examined the efficiency and outcome of MRI-guided marker placement followed by mammographic-guided radioactive seed localization (MMP/RSL) as an alternative localizatio...